Description
Introduction
The ABB FCC/S1.2.1.1 is a dedicated KNX AC Controller engineered for the efficient control of fan coil units in automated building management systems. Outfitted with two analog outputs, the controller can manage either two analog valves or a single 6-way valve drive to facilitate precise heating and cooling operations.

Designed to meet versatile room automation requirements, the device features three relay outputs for multi-speed fan control alongside a high-capacity relay output that switches additional loads up to 10 A, such as auxiliary electric heating. Four status inputs allow continuous monitoring of room parameters—including window contacts, dew point, fluid level, or temperature—and allow connection to an analog room control unit (SAR/A or SAF/A). Integrated room temperature control logic and compatibility with the ABB i-bus Tool streamline commissioning and diagnostic routines.
Key Features
- 2 Analog Outputs: Configurable for controlling two analog valves or one 6-way valve drive for heating and cooling.
- 3 Relay Outputs: Optimized specifically for fan coil fan speed management.
- 10 A Auxiliary Relay: High-capacity relay output designed for auxiliary heating or external electrical loads.
- 4 Multi-Purpose Inputs: Accepts inputs from window contacts, dew point sensors, level sensors, or temperature sensors.
- Integrated Temperature Controller: Built-in logic capable of controlling device outputs directly based on room temperature demands.
- SAR/A & SAF/A Compatibility: Direct input support for connecting one analog room control unit.
- ABB i-bus Tool Diagnostics: Facilitates advanced system testing and fast field commissioning.
Benefits
- Integrated Room Climate Control: Contains an embedded room temperature controller that directly manages system outputs for seamless HVAC automation.
- Flexible Valve Control: Two analog outputs support configuration for two analog valves or one 6-way valve drive across heating and cooling circuits.
- Dedicated High-Load Relay: Includes a 10 A relay output specifically suited for switching auxiliary heating or supplementary electric loads.
- Versatile Sensor Integration: Equipped with four inputs for real-time monitoring of window status, dew point sensors, fluid levels, or ambient temperature.
- Analog Room Unit Support: Interfaces directly with ABB SAR/A or SAF/A analog room control units via the onboard inputs.
- Advanced Software Support: Fully compatible with the ABB i-bus Tool for simplified commissioning, parameter setting, and fault diagnosis.
- Accurate BOQ Compliance: Ordering exact SKU FCC/S1.2.1.1 guarantees accurate technical specification alignment for commercial KNX projects.
Technical Specifications
Applications
Fan Coil Unit Automation: Centralized control of fan speed and analog valve positioning in commercial and residential KNX installations. Explore more ABB building automation products for professional building automation projects.
Auxiliary Heating & Status Monitoring: Ideal for spaces requiring supplementary 10 A electric heat switching combined with window, level, or dew point monitoring.
Installation Notes
- Exact Model Verification: Ensure procurement documents specify SKU FCC/S1.2.1.1 to match project bill of quantities (BOQ) and technical design.
- Wiring & Input Configuration: Connect input channels carefully according to the designated sensor type (window contact, dew point, level, temperature, or SAR/A / SAF/A unit).
- Commissioning with ABB i-bus Tool: Utilize the official ABB software tool during setup to run diagnostics, test outputs, and optimize temperature control parameters.
Developer Resources
- Official ABB Product Documentation: https://new.abb.com/products/en/2CDG110212R0011/fcc-s1-2-1-1
- KNX AC Controller Category Catalog: https://knxbazzar.com/product-category/knx-ac-controller/
- ABB KNX Brand Hub: https://knxbazzar.com/knxshop/?brand=abb
FAQ
What valve types can be controlled by the ABB FCC/S1.2.1.1?
The controller features two analog outputs that can control either two analog valves or one 6-way valve drive for heating and cooling systems. For certificates and current technical files, refer to the official product documentation.
What is the capacity of the auxiliary relay output?
The device includes a dedicated relay output capable of switching an additional load of up to 10 A, commonly used for auxiliary heating.
What sensors can be connected to the 4 input channels?
The inputs can monitor window contacts, dew point sensors, level sensors, temperature sensors, or one analog room control unit (SAR/A or SAF/A).
Does the device require an external room thermostat logic block?
No, the ABB FCC/S1.2.1.1 features an integrated room temperature controller that can directly govern the device’s outputs.
What is the exact product model?
The order/model code for this page is FCC/S1.2.1.1. Match it against project documents before purchase.
Who is the manufacturer?
This product is manufactured by ABB.
Conclusion
The ABB FCC/S1.2.1.1 KNX AC Controller delivers a comprehensive, integrated solution for managing fan coil units, combining valve outputs, fan speed switching, 10 A auxiliary load handling, and sensor monitoring in a single unit. Supported by an integrated room temperature controller and the ABB i-bus Tool, it provides system integrators with maximum flexibility and reliable control. Installers and system integrators can review our dealer and project support options.
To ensure correct deployment in your automation setup, verify your project requirements against official documentation and explore our complete catalog at https://knxbazzar.com.