The HDL M/GWASC.1 KNX Gateway is a high-performance protocol conversion gateway engineered for seamless data exchange between KNX Bus communication networks and third-party protocol devices. Built on a robust hardware architecture featuring an H3@1GHz CPU, 4GB RAM, 8GB Flash, and running on a Linux 3.2.0 Kernel, this gateway provides reliable interoperability for residential, commercial, and hospitality automation infrastructure. This device is part of our KNX system components range.

Equipped with dedicated physical interfaces—including a standard KNX terminal connector, dual RS485 connectors, an RJ45 Ethernet port, an auxiliary power supply terminal, and an SD card slot—the M/GWASC.1 enables flexible system connectivity. It allows system engineers and integrators to execute ETS programming, monitor device online/offline statuses, manage third-party product drives, and perform secure data backups across local networks and cloud servers.
Key Features
- Multi-Interface Connectivity: Equipped with 1x KNX connector, 2x RS485 connectors, 1x RJ45 Ethernet port, 1x auxiliary power supply interface, and 1x SD card slot.
- Hardware Engine: Powered by an H3 CPU running at 1GHz, 4GB RAM, 8GB Flash memory, and a Linux 3.2.0 Kernel operating system.
- Broad Protocol & Software Support: Works with HTTPS, TCP, UDP, MQTT, KNX Assistance Software, KNX ETS, ON+, and Cloud servers.
- Automation & Security Functions: Includes native automation processing, scene management options, and built-in security features.
- Third-Party Drive Management: Integrates driver management for unified control of third-party automation products.
- Comprehensive Diagnostics: Offers complete system detection, device list control feedback, and update status monitoring.
Benefits
- Enables protocol conversion between KNX Bus communication and third-party device protocols.
- Supports standard MQTT access for direct integration with third-party servers and cloud platforms.
- Provides flexible clock management, including local clock, network clock, and automatic network time synchronization.
- Delivers system status reporting by detecting device online/offline statuses and abnormal system information.
- Ensures system reliability through data backup and data recovery capabilities via APP, Cloud, and software platforms.
- Facilitates online firmware upgrades for the gateway itself as well as attached Bus devices using KNX Assistance Software.
Technical Specifications
Applications
- Residential building automation projects requiring integration between KNX TP1 networks and Ethernet or RS485 systems.
- Commercial building automation systems where central status monitoring, time synchronization, and MQTT server reporting are required.
- Hospitality management environments needing remote access, third-party product drive management, and cloud backup capabilities.
Installation Notes
- Designed for physical installation inside a standard electrical distribution box.
- Operates on a KNX Bus voltage of 21~30V DC (20mA/30V DC) and an auxiliary power supply of 20~30V DC (200mA/24V DC). Strictly do not connect to AC power.
- Use KNX terminal signal cables with a conductor diameter ranging from 0.6mm to 0.8mm for proper terminal clamping.
- Ensure operational environmental limits are maintained: operating temperature from -5°C to 45°C with non-condensing relative humidity ≤90%.
Developer Resources
- Compatible with KNX ETS software for programming and managing standard KNX TP1 field devices.
- Supports KNX Assistance Software for performing online firmware upgrades across the gateway and connected bus hardware.
- Integrates with ON+ platform and supports standard MQTT protocol access for custom third-party server developments.
FAQ
What protocols are supported by the HDL M/GWASC.1 gateway?
The HDL M/GWASC.1 supports physical KNX, RS485, and Ethernet communication channels, along with software protocols including HTTPS, TCP, UDP, and standard MQTT access to third-party servers. Explore more HDL KNX solutions for professional building automation projects.
Can I program standard KNX devices using this gateway?
Yes, KNX ETS software can program and manage standard KNX TP1 devices through the M/GWASC.1 gateway. For certificates and current technical files, refer to the manufacturer technical documentation.
What are the power supply requirements for the M/GWASC.1?
The device requires a KNX Bus voltage of 21~30V DC (20mA at 30V DC) and an auxiliary power supply of 20~30V DC (200mA at 24V DC). Connecting an AC power supply is prohibited.
Where should the gateway be physically mounted?
The HDL M/GWASC.1 gateway is designed for mounting inside a standard electrical distribution box.
What is the exact product model?
The order/model code for this page is M/GWASC.1. Match it against project documents before purchase.
Who is the manufacturer?
This product is manufactured by HDL.
Conclusion
The HDL M/GWASC.1 KNX Gateway is a comprehensive protocol conversion interface designed to bridge KNX networks with Ethernet, RS485, and cloud-based MQTT ecosystems. With robust Linux-driven hardware, multi-protocol support, and remote debugging capabilities, it provides system integrators with a reliable infrastructure solution for modern intelligent building projects. Installers and system integrators can review our professional project support options.