Description
Introduction
The HDL M/R12.16.1 is a high-performance 12-channel KNX 16A high-power switch actuator designed for residential, hospitality, and commercial building automation projects. Built around heavy-duty 50A magnetic latching relays across all output channels, this actuator delivers exceptional operational longevity, fast execution speeds, and remarkably low power consumption. Operating on a standard KNX bus voltage of 21~30V DC with a working current of 15mA at 30V DC, it efficiently controls main electrical loads across 120V/240V AC (50/60Hz) power networks. This device is part of our KNX system devices range.

Engineered for comprehensive automation setups, the unit incorporates an extensive suite of built-in control capabilities, including statistical ON time tracking, staircase lighting timers, ON/OFF delays, scene control, threshold monitoring, and curtain functions. It also features integrated logic operations (AND, OR, XOR, Gate) and PWM heating outputs. Enclosed in a flame-retardant nylon housing rated IP20, the unit installs seamlessly on a standard 35mm DIN rail and supports 3-phase load wiring.
Key Features
- 12 output channels with a 16A rated switch current per channel for lighting and heavy loads.
- Built-in 50A magnetic latching relays for energy-efficient switching performance.
- Standard KNX bus communication with dedicated red LED programming indicator.
- Flexible heating control via 1-bit or 1-byte PWM control outputs.
- Built-in logic processing supporting AND, OR, XOR, and Gate functions.
- Flame-retardant nylon housing with IP20 protection for 35mm DIN rail mounting.
- Terminals supporting 2.5–4 mm² power line cables and 0.6–0.8 mm KNX conductors.
Benefits
- High-reliability 50A magnetic latching relays provide low operational power consumption and high execution speed.
- Rated for long-term durability with over 100,000 switching operations under full load conditions.
- Supports 3-phase line connection for balanced electrical load distribution across 12 channels.
- Multifunctional control capabilities including staircase timing, ON/OFF delay, scene recall, and threshold logic.
- Integrated logic engine (AND, OR, XOR, Gate) and PWM heating controls reduce the need for separate automation modules.
- Handles high electrical surges with a maximum inrush current capacity of up to 500A.
Technical Specifications
Applications
- Commercial and hospitality high-capacity lighting circuit switching up to 16A per channel.
- Residential KNX building automation systems requiring timed staircase light and curtain control.
- HVAC zone heating control using 1-bit or 1-byte PWM signal outputs.
Installation Notes
- Mount the unit on a standard 35mm DIN rail within an IP20-compliant enclosure (unit dimensions: 90 × 216 × 64 mm).
- Connect a protective fuse or circuit breaker of 16A or less to each channel output to safeguard electrical circuits.
- For 3-phase electrical installations, connect CH1, 4, 7, 10 to Phase L1; CH2, 5, 8, 11 to Phase L2; and CH3, 6, 9, 12 to Phase L3.
- Ensure line-in and line-out wiring uses 2.5–4 mm² conductors and the KNX bus wire diameter is between 0.6 mm and 0.8 mm.
- Perform all device programming exclusively using ETS software via the integrated KNX/EIB interface.
Developer Resources
- Official engineering datasheets and user manuals are accessible via HDL Automation (https://www.hdlautomation.com).
- Technical support inquiries can be directed to [email protected].
- ETS application databases and product parameter files must be obtained directly from authorized HDL software repositories.
FAQ
How is the HDL M/R12.16.1 switch actuator programmed?
The device complies with standard KNX protocols and is programmed exclusively using ETS software via its onboard KNX/EIB interface and physical programming button. Explore more HDL KNX solutions for professional building automation projects.
What protection is required for each output channel?
Each channel supports up to 16A current, and an external fuse or circuit breaker rated 16A or lower must be connected to protect each output load. For certificates and current technical files, refer to the manufacturer technical documentation.
Can this actuator be connected across a 3-phase supply?
Yes, the 12-channel actuator supports 3-phase input connections by wiring CH1, 4, 7, 10 to Phase L1; CH2, 5, 8, 11 to Phase L2; and CH3, 6, 9, 12 to Phase L3.
What type of relays are used inside the M/R12.16.1?
The actuator utilizes 50A magnetic latching relays for reliable, low-power switching capable of handling inrush currents up to 500A.
What is the exact product model?
The order/model code for this page is M/R12.16.1. Match it against project documents before purchase.
Who is the manufacturer?
This product is manufactured by HDL.
Conclusion
The HDL M/R12.16.1 KNX 12CH 16A High Power Switch Actuator provides an exceptionally robust, multi-channel control solution for demanding electrical loads. Featuring 50A magnetic latching relays, versatile 3-phase power distribution, and full ETS logic integration, it is ideal for high-density, professional KNX building automation projects. Installers and system integrators can review our dealer and project support options.









Reviews
There are no reviews yet.