ABB HCC/S2.1.2.1 Heating/Cooling Circuit Controller (2CDG110219R0011)

KNX AC Controller

Brand: ABB
Available on backorder lead time: 1-8 weeks

€449,00

The ABB HCC/S2.1.2.1 is a 2-channel KNX heating/cooling circuit controller featuring 0…10 V analog valve outputs, 5 A pump switching relays, manual operation, and IP20 rating.

SKU: HCC/S2.1.2.1 Category: Tags: , , , Brand:
Worldwide Shipping Fast delivery to project sites
Genuine KNX Products Authorized manufacturer stock
Technical Support Expert help for dealers & installs
Secure Payments Encrypted checkout & trusted methods

Description

Introduction

The ABB HCC/S2.1.2.1 Heating/Cooling Circuit Controller (Product ID: 2CDG110219R0011) is a modular DIN-rail component (MDRC) designed for the control of heating or cooling circuits within KNX building automation systems. Operating over KNX TP, the controller features 2 channels equipped with continuous 0…10 V analog outputs to manage mixing valves alongside 5 A relay outputs for direct circuit pump switching. This device is part of our KNX AC Controller products range.

ABB HCC/S2.1.2.1

Integrated controller intelligence utilizes measured flow and return flow temperatures to calculate precise valve outputs while receiving set point temperatures directly from the KNX bus. System integrators benefit from manual operation capabilities, support for double pump system setups by bundling both channels, and full compatibility with the ABB i-bus Tool for commissioning and diagnostics.

Key Features

  • 2-fold heating and cooling circuit controller with continuous 0…10 V analog valve control outputs.
  • Integrated 5 A relay switching outputs per channel dedicated to circulation pumps.
  • Binary inputs (3 per channel) for monitoring potential-free pump status feedback contacts.
  • Built-in control algorithm using flow and return flow temperature measurements.
  • Receives temperature set points directly via KNX TP bus system.
  • Manual operation functionality and diagnostic support via ABB i-bus Tool.
  • IP20 protection degree enclosure designed for MDRC mounting.

Benefits

  • Provides continuous 0…10 V analog outputs on 2 channels for precise mixing valve position control.
  • Includes dedicated 5 A relay outputs to directly switch heating or cooling circulation pumps.
  • Supports channel bundling to easily accommodate double pump system configurations.
  • Features integrated valve protection functions to maintain long-term component reliability.
  • Allows direct local manual operation for operational checks and manual adjustments.

Technical Specifications

Specification Value
Extended Product Type HCC/S2.1.2.1
Special Functions Valve Protection
Product ID 2CDG110219R0011
Display Name HCC/S2.1.2.1
Instructions and Manuals 2CDG941187P0003
Number of Outputs 4
Number of Digital Inputs 10
Number of Inputs Analog (0 … 10 V / 4 … 20 mA) 10
Manual Operation Yes
Number of Batteries 0
Declaration of Conformity – CE 2CDK508231D2701
EAN 4016779011624
Catalog Description HCC/S2.1.2.1 Heating/Cooling Circuit Controller, 2-f, 0-10 V, man. op., MDRC
Manufacturer Description For the control of a heating or cooling circuit. The device has 2 channels, each with an analog output to control the mixing valve (0…10V) of a heating or cooling circuit as well as a relay output (5A) to switch the pump of the circuit. Via 3 binary inputs it is possible to moni…
Degree of Protection IP20
Compatible Bus Systems KNX (TP)
Manipulated Variable Continious
Product Range KNX
ETIM 9 EC001586 – Heating actuator for bus system
WEEE B2C / B2B Business To Consumer
Wiring Diagram 2CDC072034F0017
Mounting Type DIN-Rail
Data Sheet, Technical Information 2CDC508247D0211
Voltage Range 0 … 10 V DC
Maximum Switching Current 5

Applications

  • Precision temperature control of hydronic heating and cooling circuits in KNX automation networks.
  • Mixing valve regulation and pump control in single or double pump circulation loops.

Installation Notes

  • Install as a modular DIN-rail component (MDRC) inside a protective enclosure ensuring an IP20 rating.
  • Wire 0…10 V mixing valve actuators and 5 A pump supply connections to the designated output terminals.
  • Connect potential-free pump status contacts to the binary inputs for feedback monitoring.

Developer Resources

  • Instructions and Manuals Reference: 2CDG941187P0003
  • Declaration of Conformity CE: 2CDK508231D2701
  • ETIM 9 Classification: EC001586 – Heating actuator for bus system

FAQ

What bus system is the ABB HCC/S2.1.2.1 designed for?

The controller is compatible with KNX (TP) bus systems. Explore more ABB automation devices for professional building automation projects.

How many outputs does the device feature?

The device features 4 total outputs, consisting of 0…10 V analog valve outputs and 5 A relay pump outputs across its 2 channels. For certificates and current technical files, refer to the official ABB documentation.

Can the HCC/S2.1.2.1 be used with double pump systems?

Yes, by bundling both channels of the device, it can be used for double pump systems.

What is the IP protection rating for this unit?

The ABB HCC/S2.1.2.1 carries an IP20 degree of protection.

What is the exact product model?

The order/model code for this page is HCC/S2.1.2.1. Match it against project documents before purchase.

Who is the manufacturer?

This product is manufactured by ABB.

Conclusion

The ABB HCC/S2.1.2.1 Heating/Cooling Circuit Controller delivers a complete 2-channel solution for hydronic circuit regulation, combining 0…10 V mixing valve control with 5 A pump switching on the KNX TP bus. Installers and system integrators can review our become a KNX dealer options.

With support for manual operation, double pump setups, valve protection, and the ABB i-bus Tool, it provides integrators with reliable control for heating and cooling applications.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.