HDL KNX 4-Zone Dry Contact Module M/S04.1

Brand: HDL
Available on backorder lead time: 1-8 weeks

€90,00

Compact HDL M/S04.1 KNX 4-Zone Dry Contact Module featuring 4 input and 4 output channels for dry contacts, temperature sensors, 0-10V dimming, and status LEDs.

Worldwide Shipping Fast delivery to project sites
Genuine KNX Products Authorized manufacturer stock
Technical Support Expert help for dealers & installs
Secure Payments Encrypted checkout & trusted methods

Description

Introduction

The HDL M/S04.1 KNX 4-Zone Dry Contact Module is a versatile interface component engineered for KNX/EIB building automation systems. Designed in a compact form factor measuring 50mm x 50mm x 13mm for direct flush-mounted switch box installation, this module features four input channels and four output channels. The input channels accept both dry contact trigger signals and temperature sensor inputs, enabling seamless integration of conventional push buttons, switches, and environmental monitoring devices into the KNX network. This device is part of our Analogue/Binary Input Modules products range.

HDL M/S04.1 KNX dry contact module

For load control and visual feedback, the M/S04.1 provides output channels capable of delivering a 0-10V DC dimming signal to control dimmable lighting drivers or serving as LED channel state drivers and PWM outputs. Operating on standard KNX bus voltage (21 to 30V DC) with a low working current of 5mA, the module offers extensive functional parameters including switch, dimming, shutter, scene, sequence, and threshold control via standard ETS software configuration.

Key Features

  • 4 Signal Input Channels for dry contact switch triggers or temperature sensors.
  • 4 Signal Output Channels providing 0-10V DC output (3mA current) or LED state driving.
  • 3 Working Modes: Sensor control (Dry contact / Temperature), Logic control, and 0-10V Dimming control.
  • Multiple Control Types: Switch, Dimming, Shutter, Scene, Sequence, Percentage, Threshold, String, Forced, PWM, Counter, Combination, and LED status indication.
  • KNX Bus Operating Voltage: 21 to 30V DC via standard 0.6 – 0.8mm KNX bus wire.
  • Flame-Retardant ABS Enclosure rated IP20 under EN 60529 specifications.

Benefits

  • Flexible Dual Input Capability: Supports both dry contact switch triggers and TTS/APR1.0 temperature sensor inputs across 4 dedicated input channels.
  • 0-10V Dimming Integration: Delivers 0-10V DC output control to integrate 0-10V dimmable LED light fixtures and electronic ballasts directly into KNX automation.
  • Multi-Functional Output Options: Output channels can be configured for 0-10V dimming output, PWM drive, or LED status feedback indication.
  • Comprehensive Control Algorithms: Supports scene, switch, shutter, sequence, percentage, threshold, counter, string, and forced logic controls.
  • Compact Switch Box Design: Flame-retardant ABS housing with a 50mm x 50mm x 13mm profile fits standard switch boxes for clean flush installation.
  • Energy-Efficient Bus Operation: Draws low operating current (5mA at 30V DC) directly from the KNX bus line without requiring an auxiliary power source.

Technical Specifications

Specification Value
Brand HDL
Model / SKU M/S04.1
Working Voltage 21~30V DC
Working Current 5mA / 30V DC
Output Voltage 0~10V DC
0-10V Output Current 3mA
Input Sensor Compatibility Switch (Dry contact) / TTS/APR1.0 Temperature Sensor
Communication Protocol KNX/EIB
KNX Terminal Cable Diameter 0.6 – 0.8mm
Working Modes Sensor control (Dry contact / Temperature), Logic control, Dimming control (0-10V)
Control Types Switch, Dimming, Shutter, Flexible, Scene, Sequence, Percentage, Threshold, String, Forced, PWM output, Counter, Combination, LED status indication
Working Temperature -5°C ~ 45°C
Working Relative Humidity ≤90%
Storage Temperature -20°C ~ 60°C
Storage Relative Humidity ≤93%
Dimensions 50mm × 50mm × 13mm
Net Weight 24g
Housing Material Flame-retardant ABS
Installation Type Switch box installation
Protection Rating IP20 (Compliant with EN 60529)
Hardware Version A
File Edition V1.0.0
Document Issue Date June 17, 2019

Applications

Lighting and Dimming Automation: Interfacing mechanical switches and push-buttons to trigger KNX lighting actions while driving 0-10V LED dimmers with status LED feedback. Explore more HDL automation devices for professional building automation projects.

Temperature Monitoring & HVAC: Interfacing TTS/APR1.0 temperature sensors to report ambient indoor temperature values to central KNX heating/cooling controllers.

Shading and Scene Control: Connecting dry contact inputs to execute complex KNX scene sequences, shutter controls, and motorized blind commands.

Installation Notes

  • Installation Location: Mount inside standard flush switch boxes. If deployed outdoors, install within a suitable waterproof enclosure.
  • KNX Bus Wiring: Connect directly to the 21-30V DC KNX bus line using standard 0.6 – 0.8mm cable. Connection to AC power supply is strictly prohibited.
  • Wiring Topology: Hand-in-hand (daisy-chain) bus connection topology is recommended for reliability.
  • System Requirements: Configuration and commissioning must be carried out using ETS software. Temperature sensing functions require the TTS/APR1.0 temperature sensor.

Developer Resources

  • Programmable via ETS Software conforming to standard KNX protocol specifications.
  • Official HDL technical documentation reference edition V1.0.0.
  • Direct technical support available via [email protected] or www.hdlautomation.com.

FAQ

Can the HDL M/S04.1 accept both dry contacts and temperature sensors simultaneously?

Yes, its 4 signal input channels support dry contact trigger inputs as well as temperature sensing via the specified TTS/APR1.0 sensor. For certificates and current technical files, refer to the manufacturer technical documentation.

What function do the 4 output channels serve?

The 4 output channels can output 0-10V DC dimming signals (3mA current) to control dimmable fixtures, or be used for LED status drive and PWM outputs.

How is the module powered and programmed?

The module operates entirely on KNX bus power (21-30V DC, 5mA current draw) and requires ETS software for programming and commissioning.

What are the mounting dimensions and IP rating of the module?

The unit measures 50mm x 50mm x 13mm, is housed in flame-retardant ABS, carries an IP20 protection rating (EN 60529), and is intended for in-wall switch box mounting.

What is the exact product model?

The order/model code for this page is M/S04.1. Match it against project documents before purchase.

Who is the manufacturer?

This product is manufactured by HDL.

Conclusion

The HDL KNX 4-Zone Dry Contact Module M/S04.1 provides a complete input and output solution within a compact switch-box footprint. By integrating dry contact triggers, temperature sensor inputs, 0-10V dimming control, and LED status feedback in one bus-powered unit, it delivers high flexibility for residential and commercial KNX installations. Installers and system integrators can review our dealer and project support options.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.