theben BMG 6 T KNX 6-Way Binary Input MIX2 Base Module (SKU 4930230)

KNX Sensors

Brand: theben
Available on backorder lead time: 1-8 weeks

€232,00

The theben BMG 6 T KNX (SKU 4930230) is a 6-way binary input MIX2 base module for DIN rail mounting, expandable up to 18 channels for versatile KNX building control.

SKU: 4930230 Category: Tags: , , , , Brand:
Worldwide Shipping Fast delivery to project sites
Genuine KNX Products Authorized manufacturer stock
Technical Support Expert help for dealers & installs
Secure Payments Encrypted checkout & trusted methods

Description

Introduction

The theben BMG 6 T KNX (SKU 4930230) is a high-performance 6-way binary input MIX2 base module designed for commercial and high-end residential KNX building automation networks. Operating on standard KNX bus voltage with a minimal bus current consumption of ≤4 mA, this unit acts as a reliable interface for capturing switch and contact signals across building management systems. This device is part of our KNX automation components range.

theben BMG 6 T KNX

Engineered for modular flexibility, the BMG 6 T KNX serves as a foundational base module that can be expanded to manage up to 18 channels using compatible MIX2 extension units. Housed in a 4-module wide DIN rail enclosure with IP20 protection and an integrated standby power consumption of approximately 0.3 W, it delivers long-term operational efficiency and straightforward panel integration.

Key Features

  • 6-way binary input base module built on the theben MIX2 architecture.
  • Expandable channel capacity up to 18 channels using MIX2 extension modules.
  • Operates on KNX bus power (≤4 mA) alongside a main supply of 110 V AC to 240 V AC (50 Hz – 60 Hz).
  • Compact 4-module width for standard DIN rail installation.
  • Integrated auxiliary output supplying 12 V DC at 18 mA (non-SELV).
  • Supports solid wire cross-sections from 0.5 mm² to 6 mm² and stranded wire with end sleeves from 0.5 mm² to 4 mm².
  • Designed for operating ambient temperatures between -5°C and 45°C with IP20 ingress protection.

Benefits

  • Modular Scalability: Designed as a MIX2 base module capable of expanding up to 18 binary channels to meet growing automation requirements.
  • Low Energy Consumption: Features an optimized stand-by power consumption of approximately 0.3 W to reduce baseline panel energy draw.
  • Flexible Input Voltage Handling: Supports a wide voltage input range from 10 V DC to 240 V AC at 2 mA across connected field contacts.
  • Visual Input Status: Equipped with 6 front-facing LEDs that provide clear, real-time status monitoring for each individual input channel.
  • SELV Compliance Adaptability: Suitable for SELV applications when all connected inputs are implemented with SELV-compliant signal sources.

Technical Specifications

Specification Value
Operating voltage KNX Bus voltage, ≤4 mA
Operating voltage 110 V AC – 240 V AC, 50 Hz – 60 Hz
Frequency 50 – 60 Hz
Voltage inputs 10 V DC – 240 V AC 2 mA
Stand-by consumption ~0.3 W
Max. cable cross section Solid wire: 0.5 mm² (Ø 0.8) to 6 mm² | Stranded wire with end sleeve: 0.5 mm² to 4 mm²
Output 12 V DC/18 mA, no SELV
Display 6 LEDs to display the state at the input
Suitable for SELV Yes, if all inputs are connected with SELV
Information Notice EU Data Act PDF
CE declaration of conformity PDF
Data sheet PDF
Width 4
Max. cable length 100
Installation type DIN rail
Protection class II according to EN 60 730-1
Type of connection KNX bus terminal
Ambient temperature -5°C … 45°C
Operating instructions PDF
Type of protection IP 20

Applications

  • Integrating physical switches, push-buttons, and floating window/door contacts into a centralized KNX control system.
  • Interfacing high or low-voltage binary signal sources (10 V DC to 240 V AC) in industrial and commercial switchboards.
  • Scalable distribution panel layouts requiring future channel expansion via the MIX2 extension system.

Installation Notes

  • Mount standard 4-module wide unit on DIN rail within a protective IP20 distribution cabinet or enclosure.
  • Ensure input cable lengths do not exceed the maximum specification of 100 meters per input line.
  • Observe proper wire gauge limits during installation: solid wire 0.5 mm² to 6 mm², or stranded wire with end sleeves 0.5 mm² to 4 mm².

Developer Resources

  • Data sheet, CE declaration of conformity, operating instructions, and EU Data Act compliance notices are available in PDF format for technical documentation and project planning.

FAQ

How many binary input channels are available on the theben BMG 6 T KNX?

The module inherently features 6 binary input channels on the base unit and can be expanded up to 18 channels by connecting MIX2 extension modules. Explore more products from theben for professional building automation projects.

What is the supported signal voltage range for the inputs?

The inputs accept voltages ranging from 10 V DC to 240 V AC with a typical current draw of 2 mA. For certificates and current technical files, refer to the manufacturer technical documentation.

Is the auxiliary output suitable for SELV connections?

No, the 12 V DC / 18 mA output on the module is explicitly classified as non-SELV.

What is the maximum field wiring length supported by the inputs?

The module supports a maximum cable length of up to 100 meters for field input connections.

What is the exact product model?

The order/model code for this page is 4930230. Match it against project documents before purchase.

Who is the manufacturer?

This product is manufactured by theben.

Conclusion

The theben BMG 6 T KNX 6-way binary input MIX2 base module (SKU 4930230) provides system integrators with a versatile and scalable solution for processing binary field signals in KNX networks. Its ability to expand up to 18 channels combined with robust voltage handling makes it a practical asset for modern building management systems. Installers and system integrators can review our become a KNX dealer options.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.